Sporlan suction line filter drier

It’s the CORE that counts! Filter - Drier performs these vital functions: REMOVES MOISTURE — The Catch-All Filter - Drier removes moisture from the refrigerant and lubricant by adsorbing and retaining moisture deep within the desiccant granules. The blend of desiccants used in the Catch-All is specially formulated for exceptional moisture removal.


Do not install a drier with a broken core since particles might escape and damage the system. The construction of the suction line filter - drier is not significantly different from the standard liquid line filter - drier. Both driers remove the important contaminants such as moisture, dirt, aci and the products of lubricant decomposition.

All information is in portable document format (.pdf). HVAC Liquid Line Filter Drier premium universal. Sporlan Refrigeration Specialties. They remove solid contaminants and harmful acids that are created during a motor burnout. Suction Line Filter - Driers and. Skip to the end of the images gallery. When flow is in one direction, the bypass relief feature is active.


The EK Liquid Line filter drier is a premium compacted bead filter drier with a micron outlet pad for maximum filtration.

Stock up on suction line driers in the parts and supplies department of LennoxPros. Proper Liquid Line Drier Location. Moisture, acids, and solid debris are effectively captured to ensure the long life, efficiency, and capacity of today’s high performance heat pump air-conditioning systems. Fill Your Cart With Color today!


A larger size filter - drier is required than if it had been placed in the liquid line. The refrigerant velocity in the suction line is about six times the velocity in the liquid line. Therefore, a larger filter drier is required in order to maintain a sufficiently low pressure drop. Unbelievably quick response to questions.


If you do choose to LEAVE a suction drier in a system there are a few things to consider. F liquid refrigerant temperature 5o F saturated vapor temperature 3. Register to shop from our vast inventory of top brand name HVAC equipment, parts, and supplies. Parker Filter -Kore Dryer Shell P487.


Ton ROr Ton Other Gases Permanent Installation For Clean Up And New Systems. New Liquid Line Filter Drier. Condenser Blown out With Dry Nitrogen, Condenser Flushed With Rx-Flush. Here, courtesy of Emerson, is a look at the safety and installation tips related to suction line filter - driers. Read the instructions thoroughly.


Failure to follow instructions may result in filter - drier failure, system damage, or personal injury.

By continuing to visit this site you agree to our use of cookies. The PARKER steel shell suction line filter dryer is designed for system cleanup. Compact design incorporates large outside diameter shell for shorter lay-in length, and a larger core for a greater filtration area for maximum operating efficiency.


Liquid line vapor is prevented by adequately sizing liquid lines and providing sufficient subcooling. This filter - drier is an effective scale trap when used on ammonia systems. Can choose Filter core LB D-and H-for suction.


SFX series suction line filter - drier , using high-density filter can effectively filter impurities, installed in the end of the system, for the most terminals to protect the compressor. The WSL can be used on all CFC, HCFC and HFC refrigerant and lubricant combinations. CODE MODEL CONNECTIONS LIST £ DRIER CORES Valcon TFD liquid line replaceable cartridge. A liquid line filter - dryer removes unwanted moisture, aci debris and wax with minimal resistance to the flow of refrigerant and oil.


A suction line filter dryer protects the compressor from debris such as copper pipe filings, braze and solder. The features of the steel liquidline filter - drier when combined with the steel suction - line drier make the pair an excellent solution for system cleanup. SUCTION LINE FILTER DRIER $44. The two driers will quickly and effectively remove the water, sludge, acids, and solid contaminants generated when a system fails.


The obvious benefit of a suction line filter drier is the added protection given the system if a burnout should occur. The filter will effectively prevent contamination resulting from the failure from traveling back through the suction line into the other parts of the system. A filter - drier should be installed in the suction line to clean up a heat pump after severe hermetic motor burnout. The design features include: 1. The famous molded porous core for maximum contaminant removal.


C-032-S filter drier cu. Click here for more information. It is a solder connection and has gauge ports. The Extra large suction core provides the maximum running capacity and maximum filtration surface. A wide variety of suction line filter drier options are available to you, such as filter drier , refrigerant liquid receiver.


You can also choose from ce, rohs, and ul. As well as from free samples. There are 1suction line filter drier suppliers, mainly located in Asia.