How to charge a commercial refrigerator

How to charge a commercial refrigerator

This is a demo of commercial refrigeration. Refrigeration systems are life savers when functioning properly. The Crazy Romanian 36views. When the refrigerant turns from a cool vapor to a warm liquid the heat transfer completes. Connect a refrigerant charging hose kit to a can of refrigerant.


The charging hose kit includes a color-coded gauge, hose, threaded fitting that connects to the can of refrigerant , and a service valve connection that will connect to the adapter on the saddle valve. Vapor can be added to the low-pressure side of the system while it is. The refrigerant cylinder may need to be warmed in order to build up the. Warm water can be used to heat the cylinder. Never use a torch heat the refrigerant cylinder.


Even in the unlikely event of a leak and a nearby ignition source, the chance of ignition would be practically nil. Most commercial kitchens have gas-fired grills, stoves, etc. Next, use a vacuum pump to pull a deep vacuum on the system for at least minutes. Next shut the service gage valves off, and then turn the vacuum pump off.


If the vacuum holds charge the system. Only a qualified refrigeration engineer should adjust the charge on your refrigeration system. This manual is diagnosis information only. They require a very precise refrigerant charge to work at maximum efficiency. When charging in the summer we go till the glass is clear and then add pound per hp.


Dont know if thats proper but its how I was taught. If it hold steady, then charge via the low side as a gas. Once the frig reaches about 35psi, turn on the frig. Slowly keep adding the 134a over the next few minutes until you reach 8psi (5psi on Whirlpool). Wait until the freezer is at zero degrees.


Another thing say you are charging an Rrefrigeration system (large pan cooler) which requires pounds of R-22. I had a heck of a time getting that much charged in. I ran warm water over the container many times to get the pressure back up to charge in the vapor. The long and short of this is that unless you are a professional, you might miss the obvious signs that your refrigeration system needs charging.


Before charging the unit with a refrigerant, you need to pull a vacuum. It’s important that you follow all directions carefully and wear safety gloves when completing this step, as refrigerant is an ozone-depleting chemical. An incorrect temperature read could mean blocked vents or a broken thermostat.


Direct costs involved with purchasing a commercial refrigerator are simple to figure out: the cost of the unit and any associated tax or delivery charges are direct costs. Below are some of the indirect costs you will need to consider for each refrigeration option you have to choose from. Costs for testing and remediation of hazardous materials (asbestos, lea etc). Add to to the total cost above if a general contractor will supervise this project. After you determine the make, model and age of your refrigerator , take a look at the condition.


Check to if the icemaker and water dispenser work,. Look for scratches or dents on the exterior of the fridge. Maintain the deep vacuum operation for at least minutes, and then stop the vacuum pump. Leaking discharge valves of a vacuum pump cause oil to be sucked up into the copper discharge tube. Keep the vacuum pump off at least minutes to allow air to enter the system through any leaks.


Then start the vacuum pump. Check the superheat and subcooling, and make the necessary repairs. If a system has a small charge of controlled or less available refrigerant, then it. The last step in replacing the Freon in your refrigerator is to add a few tablespoons of PAG oil. This oil helps lubricate the compressor, which allows the refrigerant to easily pass through the system.


Refer to the manual to determine the exact amount of oil required for your model. Typically, you’ll add about five tablespoons. Another major concern was whether existing commercial refrigerators could be redesigned to safely and efficiently use R2without increasing the cost of the equipment to the consumer and without requiring an unreasonable amount of time and cost to make the necessary adjustments. Small refrigeration units are the most difficult to work on.


When working on a refrigeration system that uses a TXV you normally have a liquid receiver. This liquid receiver stores enough extra refrigerants to properly feed the TXV under any load condition. First of all, any time a unit needs freon there is a leak. The leak must be fixed and most times components need to be replaced as well. Unless this unit has a mfr wty then throw it out and buy yourself a new one as paying for a sealed system repair makes no sense with a freezer.


Slowly open the valve of the refrigerant bottle and then open quick connect valve, then open ball valve “G” and allow pressure to reach 60‐psi. Pressure may vary depending on ambient temperature. Close the valve on the bottle, also close the quick disconnect valve and ball valve “G” of the C‐GEARS. Check or test each item, starting with the items at the top of the page.


A capillary tube system can be charged two ways: 1. Measuring the amount of superheat at the outlet of the evaporator. You cannot charge or check the. A commercial grade refrigerator helps preserve perishable foods, eliminating waste and extending your budget! Charging Capillary Tube Systems.


We make it easy to find the perfect fridge, commercial freezer, merchandiser, or back bar cooler to help you get the most out of your stock each day.