Heat pump reversing valve replacement

Step 1: Enter Your Zip Code. Find A Pro That Fits Your Budget. Current unit was a low end Trane SEER from years ago. Need A Water Heater Expert? Amana to replace my Trane.

I have an older Nordyne heat pump (package unit). I called the local HVAC company and they said that the reversing valve has a leak and the unit has lost refrigerant. They want $8to replace it. I feel like I can replace the valve myself. My delima will be finding a valve to pelace the one on this old unit.


Be sure to check out or Amazon storefront to check out all the products and tools we use. Reversing valve replacement. A reversing valve can become stuck in a certain position, be it a mode or in-between modes, for a few reasons.

Coleman or another trusted brand of heat pump , we have the heat pump replacement parts you need. From a furnace flame sensor and. Previously we have talked about how a heat pump works. We concluded it works just like an air conditioner, moving heat from one place to another. So we have to talk about both aspects of heat pump troubleshooting.


Once you finally figure out which component is causing the problem, then you have to replace them, which can be even worse. FREE Shipping on eligible orders. The reversing valve is a regulator that changes the direction of the refrigerant inside the heat pump.


It reverses the refrigerant flow to turn the refrigeration cycle from heating to cooling or the other way around. When failing in the heating mode, the system will provide heat if the reversing valve or holding coil fails. Finally, if you are replacing the reversing valve on a system, it is best practice to replace the coil as well, especially if the replacement valve is manufactured by a different company. Replacement pool heat pump reversing valves for heating and cooling allow the pool heat pump to defrost itself and continue heating even in cold temperatures.


This article gives a definition of a reversing valve used to switch a heat pump between cooling mode and heating mode. We describe how a heat pump reversing valve works, how to find the reversing valve , and we include reversing valve troubleshooting advice and research articles. The unit cooled great for about minutes. You can submit your own service costs or heat pump repair estimates by using the form located at the bottom of the page.


The mode in which the heat pump will operate is determined by which reversing valve tubes are piped to the inside and outside heat exchangers.

Secon Get Up To Four Free Quotes. Replacing reversing valves is one of the more taxing repairs to heat pumps. I’m sure every tech has his preferred method for doing it, which probably depends on his personal level of confidence, skills and dexterity with a torch. By reversing the flow of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa. The voltages used are lethal.


A heat pump reversing valve changes the direction of the refrigerant from the inside heating cools to the pump ’s outside cooling coils, and vice versa. Troubleshooting reversing valve. HEAT PUMP REVERSING VALVE APPLICATION By: V. Training Emerson Electric Company Alco Controls Division Cooling Cycle. The way reversing valve are two valves in one, the nose valve which switches the refrigerant flow in the system. A pilot valve which controls the nose valve position threw systems pressures.


Without the reversing valve , the refrigerant would only be able to flow one way. This would limit the heat pump to either heating or cooling, just like other forced air systems. When the valve is stuck, your heat pump can’t work properly and repair is required. Without this valve , the system is stuck or frozen and can’t properly switch from one operating mode to the other. One culprit as to why your furnace is blowing cold air is that the reversing valve has broken or has failed.


A heat pump has a few extra parts that allow it to reverse the direction of heat exchange. It needs another expansion valve , and it needs a reversing valve. In a heat pump , a reversing valve controls the direction of the flow of refrigerant. Refrigerant is the chemical mixture that allows for the heat exchange to occur. This is one of the leading causes of compressor failure on heatpumps.


If the compressor was damaged while the system was running with the reversing valve stuck in the middle of the valve make sure that a new reversing valve is installed with the new. How to diagnose and replace a Lennox Heat Pump reversing valve ? On the gauges, we were getting a slow pulse, with the pressure oscillating from psi to psi. Heat pump cools poorly, seems to heat well. Instead of cooling a building, it will provide heat. The low voltage wire is removed to force the heat pump to run in cooling mode for repair even though the thermostat calls for heat , which is provided by the auxiliary heating system.


The heat pump is set to cooling mode by changing the position of its 4-way reversing valve. The solenoid activates, and helps the sliding mechanism in the valve to move. The manufacturer of your heat pump determines which direction means which mode. When a heat pump goes into defrost the reversing valve will shift into cooling mode so the outdoor unit will be defrosted. During this defrost time the heat pump defrost control should turn your indoor electric heaters on so you do not get air conditioned cold air coming out of the registers.


For example, look for signs of a problem with your heat pump defrost cycle. The defrost cycle is activated by the defrost control, which detects ice building up on the evaporator coils and uses the reversing valve to briefly reverse the heating process to melt the ice on the coils.