For closed loop chilled water systems, is treatment necessary? If so, what is the procedure for implementing chiller water treatments? This article looks at the points that need be considered when choosing a chemical dosing system for chiller water treatment (and when one might be able to avoid them). Expansion tanks are required in a closed loop heating or chilled water HVAC system to absorb the expanding fluid and limit the pressure within a heating or cooling system.
A properly sized tank will accommodate the expansion of the system fluid during the heating or cooling cycle without allowing the system to exceed critical pressure limits. WPI manufactures air and water cooled closed loop chiller systems for many applications.
A closed-loop cooling system can exchange heat with the main cooling water system in conventional tube and shell heat exchangers or plate and frame heat exchangers. In a central plant system , there are two types of water piping loops: closed and open. An open loop is from the chiller to the cooling tower. As the water flows through the tower, it is open to the atmosphere.
These types of closed loop systems are susceptible to leaks that can lead to contamination-forming corrosion and bacteria in the cooling water that may ultimately. The HydroThrift chilled water cooling system can obtain lower coolant temperatures than evaporative-type closed-loop cooling systems, since the coolant temperature is provided by a vapor compression refrigeration process rather than an evaporative process limited by ambient wet bulb temperatures. To do this, chilled water systems transfer heat from water being pumped through a piping network to a refrigerant such as R-134a or ammonia.
Four kinds of water chillers are available for commercial and industrial use.
I have a closed loop chilled water system and the static head from the centerline of the pump to the top of highest point in the piping system is only ft. I have no expansion tank in the system because my rationale is that my piping can take the pressures changes in pressure due to expansion and contraction of the water. We install closed loop due to water pumping power requirements with a deep water table.
Avatar is a tribute to my Great Grandfather, Andrew Stewart. This pin was one of his advertisements for his heating and plumbing business. Good air removal is crucial to the proper operation of any closed system.
It is generally accepted that if a minimum pressure of 4-psig is maintained at the top of a closed hydronic system , all of the above requirements will be met with the possible exception of cavitation in hot water control valves. Feedwater is a manufacturer and supplier of a range of high-quality water treatment chemicals for all types of closed circuit heating, cooling and chilled water systems. Chemical cleaning of closed loop water systems can restore efficiencies. In a perfect worl your systems would be chemically-treate exhibit excellent corrosion rates and appear crystal clear.
Figure provides an illustration of a closed loop fresh water cooling system consisting of heat exchangers, circulating pumps, orifice plates and over 3M of pipework. Doug S Dunn, Manager Building Operations. In open water systems – such as cooling towers and evaporative coolers – problems such as corrosion, scaling and fouling are apparent to anyone who takes a moment to peek through the access door. In closed water systems – such as heate chilled and geothermal loops – the interiors of boilers and pipes are permanently hidden from view.
Process Cooling Water Systems. The closed - loop evaporative system tower water requires make-up water , chemical treatment, a drain, cold weather basin heater, and blow-down just like the open- loop evaporative system discussed above. Types of Piping Systems Before piping design can be discussed in detail, you must first have an understanding of the three basic types of piping systems: closed - loop , open- loop , and once-thru.
Since glycol has a lower specific heat than water , higher concentrations of glycol in your closed loop water will reduce the heat carrying capacity of the system. Too much glycol will, therefore, increase energy costs as the system works harder to accomplish the desired heating or cooling. Accepta’s advanced closed loop and closed circuit treatment chemicals have been scientifically formulated to deliver significant operational benefits and performance improvements to heating systems and closed circuit systems including sea water cooling systems, closed chilled systems, low-pressure heating systems and other closed circuits.
Tempered Water Systems Tempered water systems found in heat pump applications have the same treatment requirements and potential problems as both chilled and hot water systems, depending on whether the system is in. It also has reduced effectiveness when chlorides and sulfides are present in the water , unless the dosage of nitrite is increased. These strategies became part of the overall approach along with more traditional strategies such as heat recovery to help achieve LEED certification. Some closed loop water systems include chilled water , engine jacket cooling, brine water systems, compressor cooling, hot water heating, power supply cooling, and other industrial processes. The only make-up water normally needed is replace water loss from leakage at pump seals, expansion tank overflow, or surface evaporation from system vents.
What Controls the Flow of the Secondary Loop ? Water Treatment Services is a leading independent UK water treatment company offering a full range of expert services for the management of closed systems, closed loop heating, cooling and closed circuit chilled water systems. Chilled Water Piping System Types (typical). Loop Heat Pump Cycles - Water Source. These systems typically make up very minimal makeup water.
A closed loop system may be either a hot water or chilled water system. An expansion tank is required in a closed loop heating or chilled water HVAC System for two very important reasons. To control or set the systems operating range. So the system water volume required is the loop time.
Certain processes require a closed - loop , whereby the process water for cooling does not come in contact with the atmospheric air. This prevents the cooling water from picking up particles that may not get filtered or even dissolved gases. See the attached diagram which outlines the key components of the chiller system. However, when leaks occur, it can be costly and difficult to maintain the treatment levels necessary for corrosion and deposit control. For more than years, chemicals such as nitrites have been used to control corrosion in closed loop chilled and hot water systems.
Closed -Circuit Cooling Systems. The chemicals attempt to coat all the metal surfaces to reduce corrosion, but do not actually reduce the real problem, dissolved oxygen. Perhaps one of the least understood functional areas of a closed - loop hydronic heating system is the expansion tank. This one item receives the least amount of attention of all the components in the heating system. Much of this inattention is due to a general lack of knowledge.
If you closed loop water system is losing and making up more water to , you may consider exploring the source of the closed loop leak. CL-is a blend of three separate corrosion inhibitors, a surfactant and an iron oxide reducing agent.